Genie fault code
Genie code H009
The platform down #1 valve circuit is shorted to battery positive. All functions are locked out. [src]
Stop: machine locked out
Likely causes
The manual lists 3 causes:
- Short in the platform down #1 harness.
- Shorted platform down #1 coil.
- Ground control (GCON) ECM.
How to fix it
Work through these in order, as the manual's troubleshooting chart does:
- Check the device on the faulted circuit (coil, horn, alarm, etc.) for a short or open circuit; replace it if it tests bad.
- If the device is good, check the harness and connector between the ground controls and the device; repair or replace them if bad.
- If the harness is also good, check the ground control (GCON) ECM and replace it if it tests bad.
Call a technician: Right away. Genie says to tag a damaged or malfunctioning machine and take it out of service, and to repair it before use.